Measure water activity in 5 minutes or less (average read time: 2.5 minutes) with ±0.003 aw accuracy. AquaLab instruments are the fastest, most precise water activity meters available.
Water activity meters must report a temperature because water activity is temperature dependent. Internal temperature control lets you set a measuring temperature between 15º - 50°C and use the instrument anywhere-even outside the QC lab.
Use the AquaLab Water Activity Meter 4TE to get lab-quality measurements at the line, receiving dock, processing plant, storage facility-anywhere you need to test and verify the safety and quality of your products and ingredients.
Put a 7.5 ml product sample in a disposable cup, place in the water activity meter, seal the sample chamber lid over the sample, and wait for vapor equilibrium.
An infrared beam focused on a tiny mirror determines the precise dewpoint temperature of the sample. That dewpoint temperature is then translated into water activity.
The sample chamber lid flips up so contaminated sensors are quick to spot and easy to clean.
The AquaLab Water Activity Meter 4TE stores time, date, and user information with every measurement and calibration, and can store up to 10,000 secure data points.
Administrative functions can be set to control access to data. Designate up to 25 unique users and passwords. Use the RS-232 serial data port to download or print data for statistical analysis and to maintain compliance records and archives.
| Water Activity Meter | Series 4 TEV | Series 4 TE | Series 3 | Lite | Pawkit |
|---|---|---|---|---|---|
| Sensor Type | Capacitance and Chilled Mirror Dewpoint | Chilled Mirror Dewpoint | Chilled Mirror Dewpoint | Capacitance Sensor | Capacitance Sensor |
| Accuracy | ±0.003aw | ±0.003aw | ±0.003aw | ±0.015aw | ±0.02aw |
| Repeatability | ±0.001aw | ±0.001aw | ±0.001aw | ±0.005aw | — |
| Resolution | ±0.001aw | ±0.001aw | ±0.001aw | ±0.001aw | ±0.01aw |
| Range | 0.030 to 1.000 aw | 0.030 to 1.000 aw | 0.030 to 1.000 aw | 0.0 to 1.000aw | 0.0 to 1.0aw |
| Measurement Time | <5 minutes | <5 minutes | <5 minutes | 5 minutes | 5 minutes |
| Temperature Control | Internal 15-50° C ±0.2° C | Internal 15-50° C ±0.2° C | None | None | None |
| Part 11 Compliance | Yes | Yes | No | No | No |
| Warranty | 3 years parts and labor | 3 years parts and labor | 3 years parts and labor | 1 year parts and labor | 1 year parts and labor (extention) |
To ensure contamination free samples, the 15ml disposable sample cups come in quantities of 100 or 500.
Print data straight from AquaLab in real time.
The printer has a 4.5 x 5 inch footprint (it's just over 2 inches tall), prints up to 40 characters per line, and uses 2.25 adding machine paper.
Reduce reading time by pre-equlibrating the sample to instrument temperature on the temperature equilibration plate. The equilibration plate holds samples at any preset temperature between -10 and 100 º C.
Protect your AquaLab during transport. Airtight/watertight seal with extra thick wall construction. The series specific foam cutouts allow for a perfect fit. Specify series and model numbers when ordering.
Email: support@decagon.com
Phone: 800-755-2751 or
509-332-2756
Fax: 509-332-5158
Or send us an information request: